Bug 945 - Data Source not switchable to Manual
Summary: Data Source not switchable to Manual
Status: RESOLVED FIXED
Alias: None
Product: VCL TeeChart
Classification: Unclassified
Component: Series (show other bugs)
Version: 140923
Hardware: PC Windows
: Normal normal
Target Milestone: ---
Assignee: Steema Issue Manager
URL:
Keywords:
Depends on:
Blocks:
 
Reported: 2014-10-06 08:24 EDT by Bert Kreisel
Modified: 2014-10-10 13:34 EDT (History)
2 users (show)

See Also:
Chart Series: ---
Delphi / C++ Builder RAD IDE Version: RAD XE5


Attachments

Note You need to log in before you can comment on or make changes to this bug.
Description Bert Kreisel 2014-10-06 08:24:36 EDT
A Series with a Data Source (f.i. Text File) can't be switched to Manual. The Data Source will not be deleted in CBDataSourcestyleChange because the Series is not the Owner of the Data Source.
Comment 1 sandra pazos 2014-10-07 10:55:07 EDT
Hello Bert,

I’m not sure to understand what the problem is. Could you please arrange for us a simple project where the problem appears, because we can check it here? If you can't make simple project, please explain exactly how we can reproduce the problem here. 

Thanks in advance,
Comment 2 Bert Kreisel 2014-10-08 03:28:33 EDT
Steps to reproduce the problem:

1. Start TeeChartOffice
2. Edit -> Series -> Add normal Serie (now we have serie1 and serie2)
3. Set Series1 -> Data Source to Function, add Series2, Apply
4. Try to switch the Data Source of Serie1 back to Manual (only seems to be ok)
5. Select any other entry in the editor (f.i. General)
6. Go back to Series1 Data Source and you don't see Manual!

The problem is the same for anny other Data Source (f.i. Text File). You can't switch this to Manual.

Thanks in advance,