Bug 945

Summary: Data Source not switchable to Manual
Product: VCL TeeChart Reporter: Bert Kreisel <bert.kreisel>
Component: SeriesAssignee: Steema Issue Manager <issuemanager>
Status: RESOLVED FIXED    
Severity: normal CC: david, sandra
Priority: Normal    
Version: 140923   
Target Milestone: ---   
Hardware: PC   
OS: Windows   
Chart Series: --- Delphi / C++ Builder RAD IDE Version: RAD XE5

Description Bert Kreisel 2014-10-06 08:24:36 EDT
A Series with a Data Source (f.i. Text File) can't be switched to Manual. The Data Source will not be deleted in CBDataSourcestyleChange because the Series is not the Owner of the Data Source.
Comment 1 sandra pazos 2014-10-07 10:55:07 EDT
Hello Bert,

I’m not sure to understand what the problem is. Could you please arrange for us a simple project where the problem appears, because we can check it here? If you can't make simple project, please explain exactly how we can reproduce the problem here. 

Thanks in advance,
Comment 2 Bert Kreisel 2014-10-08 03:28:33 EDT
Steps to reproduce the problem:

1. Start TeeChartOffice
2. Edit -> Series -> Add normal Serie (now we have serie1 and serie2)
3. Set Series1 -> Data Source to Function, add Series2, Apply
4. Try to switch the Data Source of Serie1 back to Manual (only seems to be ok)
5. Select any other entry in the editor (f.i. General)
6. Go back to Series1 Data Source and you don't see Manual!

The problem is the same for anny other Data Source (f.i. Text File). You can't switch this to Manual.

Thanks in advance,